InFocus MT3000(B) Automobile User Manual


 
NEW EMERGENCY RAISE
PROCEDURES
FOR
ELECTRIC MACHINES
This Emergency Procedure to be used anytime if/when the Motion Platform lowers in a
abnormal way, ie: Contacts the stands, floor or is stuck half way between all the way UP
or DWN.
1. Anytime an abnormal action occurs on the motion platform the operator
MUST immediately depress the E-Stop on the side of the command console.
2. Verify that the E-Stop is depressed.
3. On the Lower Right corner of the Task Bar right click with the mouse on the
icon that contains a checkmark in a green circle. This opens a Properties
window.
4. Click on Emergency Raise, another control window will open up showing a
STOP and RAISE icon.
5. Pull out the E-Stop on side of command console. Verify immediately that
there is no motion on the platform. If there is push E-Stop back in
immediately and then back out, this will reset the brakes on all drive motors.
6. Click on RAISE icon, the unit platform will rise approximately ½ to ¾ of an
inch at a time. It will do so until it contacts the upper limit sensors and stop.
7. When motion platform is all the way UP, DEPRESS E-STOP.
8. Manually level the platform in Pitch and Roll.
9. Lower the platform using the manual lowering procedure, by turning the brake
lever on rear of lift motor clockwise slowly until the platform lowers.
10. Lower all the way. When down on the stands open the cockpit and help
patrons out.
11. Call Maintenance for repair and/or unit testing to certify that this unit is safe
to operate.