Symbol Technologies VRC 6940 Automobile Accessories User Manual


 
A-18
VRC 6940 Product Reference Guide
Boot Mode Options:
Power Management
If power management is set to PSP (the default), the radio only powers up if there is traffic
on the network. Because the radio is not always in a ready state when a message is sent to it,
PSP mode slows response times. If power management is set to CAM, the radio is always
ready to receive. To configure Power Management:
1. Select Pwr Management to display the screen shown in Figure A-21.
2. Use the UP or DOWN arrow keys to select
PSP
or
CAM
, then press ENTER.
3. Press CLEAR or ENTER to return to the main menu.
Figure A-21. Configuring Power Management
Boot Broadcasts a TCP/IP BOOTP request to the network. If they
have been configured to do so, boot servers on the network
send a response. The terminal accepts the first valid response it
receives, which contains a terminal IP address and other
network parameters that override any parameters entered
through CFG24.
DHCP Uses the same process as the Boot option but uses the Dynamic
Host Configuration Protocol.
Manual
Entry
The terminal does not broadcast any configuration messages to
the network. It uses the current network parameter values
(saved in the radio flash) to connect to the network.
PWER MANAGEMENT
Radio Pwr Mode:
PSP
BkSp, CLR, Enter