SPECIFICATIONS
Output Current Rating 60 amps continuous @ 25°C ambient
Default Battery System Voltage 12, 24, 36, 48 or 60 VDC (adjustable)
PV open circuit voltage 150 VDC Maximum (ETL Rating for UL1741
Standard); operational max = 141 VDC
temperature corrrected VOC
Standby power consumption Less than 1 watt typical
Recharging regulation methods Five stage—Bulk, Absorption, Battery Full, Float,
and Equalization
Voltage regulation set points 13-80VDC
Temperature compensation With optional RTS sensor 5 millivolts °C per
2V cell
Voltage step down capability Down convert from any PV array voltage within
PV voc limits of 141 VDC to any battery system
voltage
Examples: 72V array to 24V; 60V array to 48V
Digital Display 4 line 20 character per line backlit LCD display
Remote Interface RJ45 modular connector Cat 5 cable 8 wire
Operating Temperature Range* -40° to 60°C de-rated above 25°C
Environmental Rating Indoor type 1
Conduit knockouts Two 1” on the back; one 1” on each
side; two ” on the bottom
Warranty Two years parts and labor, optional extended
warranty available
Dimensions MX60—13.5”H x 5.75”W x 4”D
Boxed—18”H x 11W x 8”D
Weight MX60—12 pounds Boxed—15 pounds