Secondary LOG2 Screen
The Secondary Log2 screen shows the basic recharging state of the MX60 (EQ, FLOAT) time in
minutes, and the daily maximum (HighWatts) wattage seen by the MX60 during the day.
When initiated, EQ
information will be
displayed here.
The lower and upper
battery temperature
compensation voltage
is visible and active
only when the mode
is set to LMIT (5.11
Rev).
NOTE: Float time does not accumulate (1) when the MX60 is sleeping or (2) when an external power
source keeps the battery above  oat voltage.
The present day’s time—
in minutes—spent in
Float stage.
This value is the peak
daily Watts seen by the
MX60.
Press soft key #3 to display the accumulated total
kWh reading in AC or DC the Data
Logging screen.
DCkWh (default) shows DC kiloWatthours and
should be used in a non-grid-tied system.
ACkWh is used with a grid-tied system. The
heading in the logging screen will change to
TotalKWh AC.
TotalKWh AC is based on a 90% inverter
e ciency (1kWH DC = 0.9kWH AC).
0000 oat Tmin
0705 HighWatts
Lo 13.2 Hi 14.8
BACK DCkWh