34
BACKLIGHT
AUTO (default) leaves backlight and soft keys on for 60
seconds whenever any soft key is pressed (pressing any
soft key when the LCD is not lighted does not change
any settings).
ON and OFF states are also available.
Press the #1soft key twice to return to the MAIN Menu
screen
Press the < > soft key to move the asterisk to the EQ
option. When the asterisk is to the left of EQ, press the
<GO> soft key.
EQ—BATTERY EQUALIZE
The intent of an equalization charge is to bring all battery cells to an equal voltage. Sealed batteries
should not be equalized unless speci cally instructed by the manufacturer. Shut o or minimize all AC
and/or DC loads when equalizing and be sure the EQ voltage will not damage any DC load. If possible,
ensure the EQ cycle starts and stops the same day it is initiated or unnecessary battery gassing can
occur.
Occasional equalization extends the life of  ooded electrolyte batteries.
Proceed with caution! A vent fan is recommended in enclosed spaces.
The MX60 allows the user to set voltages and times of equalization process.
Both manual and auto modes are available.
• EQ is not battery temperature compensated.
Always check the electrolyte level in the batteries before and after equalizing.
BACKLIGHT CONTROL
ALWAYS
EXIT AUTO ON OFF
Charger Aux *Light
EQ Misc Optimize
Logging Log2