3-20 DISASSEMBLY, REASSEMBLY, INSPECTION, AND MAINTENANCE
Charging System
Regulator Inspection
•
Disconnect the connector from the regulator.
•
Set the measurement range of the hand tester to R 1k and
measure the resistance at the areas given in the table below.
•
Although this test is not sufficient to determine the integrity of the
regulator, it will serve as a criterion for making a judgment.
Regulator Internal Resistance (k )
Tester
Negative
(–)
Tester Positive (+) Terminal
Terminal + A – ~ ~ B
+ --- ∞ ∞ ∞ ∞ ∞
A 4~20 --- 0.2 ~ 1 1~5 1~5 200 ~ ∞
– 3~15 0.2 ~ 1 --- 1~5 1~5 200 ~ ∞
~ 1~5 ∞ ∞ --- ∞ ∞
~ 1~5 ∞ ∞ ∞ --- ∞
B 10~50 1~5 1.5 ~ 7.5 4~20 4~20 ---
If the measured resistance differs from the table above, replace the
regulator.
A: Key Switch
B: Charging Indicator Light