2. C
-
series Tile
>
2.3 Assembly & Mounting
2.3 Assembly & Mounting
The rear of a C-series tile contains the rigging hardware necessary for temporary hanging or stacking in a staging application, as well as hardware for
permanent installation in an architectural setting.
1 Carrying handle. Folds away when not in use.
2 Latch hook and lever. Locks multiple C
-series tiles together.
3 Power & data input. Combined AC power & data input via black PXL Cable socket.
4 Center mount point with rotary latch. Attaches to secondary steel for fixed or architectural installations.
5 Latch catch receiver. Accepts the latch hook for locking multiple tiles together.
6 Radius adjustment dowel. Interchangeable pin available in differing angles to enable horizontally curved installations.
7 Breather valve. Allows air to breath through waterproof, gas-
permeable membrane. One valve on each side of tile.
8 Power & data output. Combined AC power & data output via white PXL Cable socket.
9 Tile status indicator. Color indicates tile status.
WARNING
Do not hang more than 25 panels (10 m) tall with the integral rigging hardware.
No lifting point should support more than 100 tiles (1433 lb / 650 kg).
When using light duty headers, refer to Appendix 5, Light Duty Rigging Info to calculate the maximum number of panels.
Displays >10 m tall require an auxiliary frame system not supplied by Barco.
Failure to equalize the load among all pickup points could result in serious injury.