3 - 54
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
NOTE:
_
Since MF batteries are sealed, it is not possi-
ble to check the charge state of the battery by
measuring the specific gravity of the electro-
lyte. Therefore, the charge of the battery has to
be checked by measuring the voltage at the
battery terminals.
1. Remove:
• seat
Refer to “COWLING AND COVER”.
• battery cover
Refer to “AIR FILTER CASE”.
2. Disconnect:
• battery leads
(from the battery terminals)
CAUTION:
_
First, disconnect the negative battery lead
1
, then the positive battery lead
2
.
3. Remove:
• battery
4. Check:
• battery charge
▼▼▼▼ ▼ ▼▼▼▼ ▼ ▼▼▼▼ ▼ ▼▼▼▼ ▼ ▼▼▼▼ ▼ ▼▼▼▼ ▼▼▼
a. Connect a pocket tester to the battery termi-
nals.
NOTE:
_
• The charge state of an MF battery can be
checked by measuring its open-circuit volt-
age (i.e., the voltage when the positive bat-
tery terminal is disconnected).
• No charging is necessary when the open-cir-
cuit voltage equals or exceeds 12.8 V.
b. Check the charge of the battery, as shown
in the charts and the following example.
Example
c. Open-circuit voltage = 12.0 V
d. Charging time = 6.5 hours
e. Charge of the battery = 20 ~ 30%
▲▲▲▲ ▲ ▲▲▲▲ ▲ ▲▲▲▲ ▲ ▲▲▲▲ ▲ ▲▲▲▲ ▲ ▲▲▲▲ ▲▲▲
Positive tester probe
→
positive battery terminal
Negative tester probe
→
negative battery terminal
2
1
Relationship between the open-circuit voltage and the
charging time at 20 °C (68 °F)
These values vary with the temperature, the condition of the battery
plates, and the electrolyte level.
Open-circuit voltage (V)
Charging time (hours)