Symmetricom XL-GPS GPS Receiver User Manual


 
94 997-01530-01, Rev. C-25, Jan 2008
SSSSSSSSSSSS SSSS SSSSSS SSSSSSS S SSS SSSSSSS
1
F110 performs two separate functions:
Configure the J1 input port for a TIET signal
Display TIET information.
Keypad
J1 Input Config: Displays “DISABLE” if the function has not been purchased and installed.
Displays “TIET” if the TIET option has been purchased and installed.
J1 Select Function: If TIET is enabled, select DISPLAY TIET MEAS to display TIET information
such as Time Interval or Event Time, or select J1 INPUT CONFIG to configure the J1 for a TIET
input signal.
Select TIET Measurement: If DISPLAY TIET MEAS was selected, select whether to display
TIME INTERVAL or EVENT TIMING on the front panel.
J1 Input Impedance: For short runs (<200 ft.), select 100 kΩ. For long runs (>200 ft.), select
50Ω.
Input Polarity: Positive only.
Upon changing the settings, the last display prompt asks:
Save Changes?: (Yes, No) Yes applies the changes. No cancels the changes.
For J1 specifications, see
1 PPS Out” on page 6.
Notes: Stray capacitance loading on the J1 input adversely impacts TIET measurements.
Command Line
Use F110 to query or configure the J1 TIET input, or to query TIET information.
To request the J1 Input Configuration, enter:
F110<CR>
The port responds with the ASCII character string:
F110<S>TIET<S><Impedance><S><Sign><CR><LF>
(when TIET option is enabled and J1 has a TIET input)
Where the F110 entry and request formats are defined as:
F = ASCII character F.
110 = function number.
TIET = ASCII character string "TIET" for configuring J1 for TIET measurement
<S> = ASCII space character one or more