EP-15 Fluid Level Calibration
The default calibration for the EP-15 Fluid Level is just as accurate as
standard fluid level gauges. If, however, the tank has an irregular
shape or greater accuracy is needed, calibration is recommended. There
are three calibration options: 2-Point, 3-Point and 5-Point.
2-Point Calibration
A 2-point calibration is best suited for rectangular or square-shaped
tanks, where the capacity of the top half of the tank matches the capac-
ity in the lower half of the tank. In a two-point calibration, you will set
two points, one each for empty and full levels.
You can begin calibration at either of the two points, but we recom-
mend starting with an empty tank. You will fill the tank to complete
calibration.
1. Press
MENU| MENU, use ↓ ↑ to select NMEA 2000 and press ENT.
2. Highlight
BUS SETUP and press ENT, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page.
3. Select the EP-15 Fluid Level and press
ENT.
4. Press ↓ to select
CALIBRATE and press ENT. The Device Calibration
menu will appear. Instructions on Calibration will be listed at the top
of the menu.
5. Highlight
NUM PTS, press ENT and select 2. Press ENT.
6.
Select FLUID LEVEL, press ENT, then select EMPTY LEVEL and press ENT.
7. Make sure the fuel tank is empty, highlight CALIBRATE and press ENT.
The following message will appear: Empty Level Calibration Com-
pleted.
Press ENT.
8. Fill up your tank, highlight FLUID LEVEL and press ENT.
9. Select FULL LEVEL and press ENT. Highlight CALIBRATE and press ENT.
10.
The following message will appear: Full level Calibration Com-
pleted.
Press ENT, then press EXIT repeatedly to get back to the main
display.