Matrix Modules Command Reference 53Chapter 4
ARM
The ARM subsystem selects the number of scanning cycles (1 to 32,767)
for each INITiate command.
Subsystem Syntax ARM
:COUNt <number> MIN | MAX
:COUNt? [<MIN | MAX>]
ARM:COUNt
ARM:COUNt <number> MIN | MAX allows scanning to occur a multiple of
times (1 to 32,767) with one INITiate command when INITiate:CONTinuous
OFF | 0 is set. MIN sets 1 cycle and MAX sets 32,767 cycles.
Parameters
Comments Number of Scans: Use only numeric values between 1 and 32767, MIN, or
MAX for the number of scanning cycles.
Related Commands: ABORt, INITiate[:IMMediate]
*RST Condition: ARM:COUNt 1
Example Setting Ten Scanning Cycles
This example sets a relay matrix for 10 scans of channels 10000 through
10003. When the scan sequence completes, channels 10000 through
10003 are closed.
ARM:COUN 10
! Set 10 scans per INIT command
SCAN(@10000:10003)
! Scan channels 10000-10003
INIT
! Start scan, close channel 10000
Name Type Range of Values Default Value
<number> numeric
1 - 32,767 | MIN | MAX
1