Agilent Technologies E1465A Automobile Parts User Manual


 
Matrix Modules Specifications 81Appendix A
Appendix A
Matrix Modules Specifications
General
Module Size/Device Type:
C-size VXIbus, Register based, A16/D16, Interrupter
(levels 1-7, jumper selectable)
Relay Life:
@ No Load: 5 x 10
7
Operations
@ Full Load: 10
5
Operations
Power Requirements:
Voltage: +5 V
+12 V
Peak Module Current (A) 0.10 0.18
Watts/slot: 5 W
Cooling/slot: 0.08 mm H
2
0 @ 0.42 Liter/sec for 10
o
C rise
Operating Temperature: 0
°
- 55
°
C
Operating Humidity: 65% RH, 0
°
- 40
°
C
Terminals:
Screw type, maximum wire size 18 AWG
Input Characteristics
Maximum Voltage Terminal to Terminal:
200 Vdc or 170 Vac
rms
(238 Vac peak to peak)
Maximum Voltage Terminal to Chassis:
200 Vdc or 170 Vac
rms
(238 Vac peak to peak)
Maximum Current per Channel (non-inductive):
1 Adc or 1 A ac peak
Maximum Power per Channel:
30 Wdc or 62.5 VA ac resistive load
DC Performance
Closed Channel Resistance:
Initial: <4.0
W
End of Life: <10.0 W
Insulation Resistance
(between any two points, single module):
10
8
W at 40°C, 95% RH
10
9
W at 25°C, 40% RH
Thermal Offset per Channel:
<5
mV (differential H-L)
AC Performance
Bandwidth (-3 dB): Zload = Zsource = 50 W
>10 MHz (for worst crosspoint)
Closed Channel Capacitance (Hi-Low, Lo-Chassis):
HI to Lo: <270 pF
Hi to GND: <430 pF
Lo to GND: <440 pF
Crosstalk between Channels:
See tables on next page