Agilent Technologies E1465A Automobile Parts User Manual


 
Matrix Modules Command Reference 57Chapter 4
INITiate
The INITiate command subsystem selects continuous scanning cycles and
starts the scanning cycle.
Subsystem Syntax INITiate
:CONTinuous <mode>
:CONTinuous?
[:IMMediate]
INITiate:CONTinuous
INITiate:CONTinuous <mode> enables or disables continuous scanning
cycles for the matrix modules.
Parameters
Comments Continuous Scanning Operation: Continuous scanning is enabled with
INITiate:CONTinuous ON or INITiate:CONTinuous 1. Sending
INITiate:IMMediate closes the first channel in the channel list. Each trigger
from the source specified by TRIGger:SOURce advances the scan through
the channel list. A trigger at the end of the channel list closes the first
channel in the channel list and the scan cycle repeats.
Noncontinuous Scanning Operation: Noncontinuous scanning is enabled
with INITiate:CONTinuous OFF or INITiate:CONTinuous 0. Sending
INITiate:IMMediate closes the first channel in the channel list. Each trigger
from the source specified by TRIGger:SOURce advances the scan through
the channel list. At the end of the scanning cycle, the last channel in the
channel list is opened.
Stopping Continuous Scan: See the ABORt command.
Related Commands: ABORt, ARM:COUNt, TRIGger:SOURce
*RST Condition: INITiate:CONTinuous OFF | 0
Name Type Range of Values Default Value
<mode>boolean
ON | OFF | 1 | 0 OFF | 0