PowerTec 1000AR Automobile User Manual


 
Model
1000AR
Installation and Operation Manual
P
AGE
31
OFFICIAL 6/4/2001
INSTALLATION CHECKLIST
Is the Model 1000AR securely mounted in a vertical position (fuses up) [page 5]?
Is there a clear path for airflow through the base heatsink and through the chassis
[page 5]
?
Is the temperature of the air surrounding the drive within specifications
[page 5]
?
Is the AC power source for the drive of the proper voltage, frequency, and capacity
[page 7]
?
Is the motor securely mounted and aligned
[motor manual]
?
Is the drive and motor system properly grounded
[pages 7 and 9]
?
Are the motor leads connected in the proper order
[page 9]
?
Is the cable from the motor to the drive properly connected
[page 9]
?
Is the bus loader installed and properly connected
[page 11]
?
Are the regen resistors properly installed and connected
[page 11]
?
If an Output or Dynamic Braking Contactor is used, is it properly interlocked
[page13]
?
If Dynamic Braking is used, are the resistors properly installed and wired
[page13]
?
Is the motor thermal properly wired to the drive
[pages 14 and 15]
?
Is the Emergency Stop button properly installed
[pages 14 and 15]
?
Are other drive controls properly wired
[pages 14 and 15]
?
Is the Speed Reference source properly wired in
[page 19 or 21]
?
Is the motor mechanically safe to run (an unloaded motor is recommended) ?
Is the machine safe to run and are all personnel clear ?
Proceed to the Start Up section.