LXI LX7007 GPS Receiver User Manual


 
LX 7007 pro IGC V1.0 Apr.2005
Page 57
3.2 Communication with PDA
A completely separated com. port with his own 9P sub D connector is situated on the rear side of the unit. LX 7007 has a
built in DC/DC converter which ensures 5V power for PDA. A standard LX cable (1638 or 1636) will connect
practically all iPAQ devices to LX 7007 without any additionally works. Main functionality of the port:
Sending of NMEA data to PDA, see capture SETUP/NMEA
Exchanging of data LX 7007 – PDA including flight downloading
Use free PDA program ConnectLX or Downloader from FlywithCE.
Note!
Cable to connect LX 7007 and mostly all types of iPAQ is delivery included,
Cable LX 1638 will connect:
H22xx, H38xx, H39xx, H41xx, H43xx, H51xx, H54xx in H55xx, H4700
Cable 1636 will connect:
36xx, 37xx,31xx
If not specified cable 1638 will be delivered. After special request cables with open wires can be delivered to allow
connection of third party PDAs.
3.2.1 Connect procedure to PDA
Run ConnectLX and select Device type like COLIBRI…..LX7000, define com port and other necessary parameters,
com speed doesn’t matter.
Select TRANSFER/PDA on LX 7007and press Enter. After AUTODECT procedure a very typical message
CONNECT will appear on the LX 7007 screen. Define art of transfer using Actions menu on PDA and proceed with
next. For details see ConnectMe manual on www.seeyou.ws.
Note!
Having problems with connect, make sure those other applications like SeeYou Mobile….. are regularly closed,
otherwise they occupies the com port. Close the applications using EXIT.