Furuno RP180 GPS Receiver User Manual


 
12. INSTALLATION
12-5
10. Turn on the radar and conduct the self test by pressing [MENU], [0], [0], [0], [0], [2], [2].
Check the radar program number, at the top of the screen. If it is younger than the
program number recorded on the floppy disk (supplied), the program must be updated. If
updating is not required, no further adjustment is necessary; turn off the radar.
FR-1500 M-3 SERIES TEST
1. Program No. 03591521XX*
2. ROM Check OK EPA OK
3. RAM Check OK
4. Antenna Rotation rpm
5. TX Trigger Frequency 3000Hz
6. Video Level 000
7. Video Signal OK
ARP TEST
1. Program No. 18590411XX* 18590421XX*
2. ROM Check OK OK
3. RAM Check OK
4. Speed Log OK 0.0KT
5. Course OK
6. Trigger OK
7. Video Signal OK
8. Bearing Pulse OK
9. Heading Pulse OK
10. Minimum Hit 0003
11. Scan Time 0804
12. Manual Acq. 00
13. Auto Acq. 00
14. FE-Data 1 0000
15. FE-Data 2 0000
000
X: 000
Y: 000
000
Press MENU key to escape
Press ENTER key to check CRT.
*: XX = Program Version No.
Self test results