Barnett Engineering CV2 Automobile Alarm User Manual


 
Getting Started 1-3
B1272M001
BARNETT ENGINEERING LTD. ProTalk Cv2
Table 1 Mode Comparison
Function Advanced Mode Basic Mode
Input debounce Independent for each input Part of Alarms - same setting for all
Input NO/NC Independent for each input Part of Alarms - same setting for all
Input type 8 inputs - 1 analog, 4 digital types 8 Alarms - 1 digital type only
Output type 8 outputs - On/Off or timed 8 Controls - 3 On/Off or timed
4 can be special function 5 always special function
Groups 6 groups each with separate Not used
Acknowledge code Part of Directories
Interrogate code Part of Directories
Short and long timer Part of Directories - Cycle timer
Shift control ---
Group enable ---
Ack request enable ---
Auto Ack enable ---
Points 30 points, can be any input/output Not used
Using group ---
Enable Part of Alarms - same setting for all
Latched Part of Alarms - same setting for all
DTMF tag ---
Alarms Not used 8 alarms
--- Using Directory A/B or disabled
--- NO/NC - same for all Alarms
--- Momentary or Latched - same for all
Directories 6 directories 2 directories
Dial Directories commands can be Basic
Voice or Advanced when programming in
DTMF the Basic mode. Only phone
Wait numbers can be programmed in
Alert Basic mode.
Signal Acknowledge code
Answer Interrogate code
--- Cycle Timer
General Rings before answer Rings before answer
Call progress enable Call progress enable
Access code Access code
Temporary Ack time Temporary Ack time
Enable Modem code Enable Modem code
Security levels
Shift change code