Barnett Engineering CV2 Automobile Alarm User Manual


 
Configuration using the PC 4-15
B1272M001 BARNETT ENGINEERING LTD. ProTalk Cv2
separated by 100 msec of quiet.
Alert must be preceded by a Dial command; it cannot be the first entry in the list. It can be
used more than once in a list.
Voice
The Voice command causes stored voice messages for the Site ID, Group IDs and any
points in the alarm state to be spoken. If Voice is the only command after Dial, the Cv2
will speak the alarm message three times or for one minute, whichever comes first.
Voice must be preceded by a Dial command; it cannot be the first entry in the list. It can be
used only once in a list.
Answer
The Answer command causes the Cv2 to monitor the called line for activity before it begins
to speak the alarm message. If the Cv2 is calling a voice or numeric paging terminal with
an automated attendant, the Answer command will cause it to wait for the voice prompt
before transmitting the pager number. Do not place the Answer command immediately
after a Dial command if Call Progress is selected in the General section. This will cause
the Cv2 to look for a voice response twice in a row and may prevent alarm announcements.
Signal
If a DTMF tag is programmed for a point and the Signal command is set, then only the
DTMF tag for this point will be sent and the voice message will not be spoken.
Signal must be preceded by a Dial command; it cannot be the first entry in the list. It can
be used once in a list.
Delete
Delete removes the selected command from the list. Commands that followed the deleted
one are moved to fill in the empty space. If the first command is selected, then Delete will
remove all commands for this line.
4.7.5 General
Settings that affect the overall operation of the Cv2 are entered in the General section.
Site Name
The Site Name is a 16 character text field that allows you to enter a description of the site
where the Cv2 is to be located. Other than viewing in the General dialog box, this name
has no other use. Normally it is set to match the voice message that is programmed as the
Site Identifier.
Default Site Name: an empty text string.
Security Level
The Security level setting determines the actions that the Cv2 will perform when it receives
an incoming call.
Level 1 The Cv2 announces the Site ID, any groups that are in the alarm state and
prompts the caller to “Enter Command Code”. An Access Code is not
required.
Level 2 When the incoming call is answered by the Cv2, only the Site ID is
announced; for further access to the Cv2 the caller must enter the Access
Code.