Auto Page C3-RS1100 Automobile Alarm User Manual


 
C3 RS1100REV. A
33
(H6/8) of the Remote Start Unit.
F. Connect terminal 86 of the relay to a fused + 12 volt constant battery source.
G. Connect terminal 87 of the relay to the Chime Module side of the previously cut
wire in step D.
H. Connect terminal 85 of the relay to the Drivers Door side of the pin switch wire
previously cut in step B.
Note: A second 4003 series diode may be required to maintain the integrity of the hood
open, shut down circuit. If this is the case, it must be installed as shown in the
diagram above. The anode (Non Stripped) side must be connected to the WHITE/
BLACK wire (H6/8) of the Remote Start Unit. The cathode (Striped) side must be
connected to the hood pin switch. If the hood pin switch is also used for an alarm
trigger input, be certain to use the dual diode assembly packaged with the Remote
Start Unit as shown in this installation guide.
METHOD 2
Ignition Key In Sensor
Switch Closes with Key
In Ignition Cylinder
Switch
Connected to (-
) Negative
Safety Input Wire
White/ Black (H6/20)
To Hood Pin Switch
Safety Shut Down (H10/1)
1N4003
To connect to the key in sensor circuit as shown for method 2:
A. Locate the control wire that connects the driver’s door pin switch to the key in
sensor switch.
B. Cut this wire and connect the ignition cylinder side to chassis ground.
C. Locate the key in sensor switch wire that connects the chime module to the
ignition cylinder.
D. Cut this wire and connect the ignition cylinder side to the Remote Start Negative
Safety Shut down wire WHITE/ BLACK (H6/20), using a 4003 series diode as
shown above.
Note: A second 4003 series diode may be required to maintain the integrity of the hood
open, shut down circuit. If this is the case, it must be installed as shown in the
diagram above. The anode (Non Striped) side must be connected to the WHITE/
BLACK wire (H6/20) of the Remote Start Unit. The cathode (Striped) side must be
connected to the hood pin s witch. If the hood pin switch is also used for an alarm
trigger input, be certain to use the dual diode assembly packaged with the Remote
Start Unit as shown in this installation guide.
AFTER THE CONNECTION OF THE NEUTRAL START SAFETY WIRE AS INDICATED
IN ANY OF THE PREVIUOS ALTERNATE CONFIGURATINS, THIS CIRCUIT MUST BE
TESTED FOR OPERATION.
Retest by following the steps outlined in the NEUTRAL START SAFETY TEST shown in
this manual.