Auto Page C3-RS1100 Automobile Alarm User Manual


 
C3 RS1100REV. A
16
The WHITE/BLACK wire provides an
instant shutdown for the remote start,
whenever it is grounded. Connect the
wire to the hood pin switch previously
installed. This wire must be routed
though a grommet in the firewall and
connected to the hood pin switch. If
the pin switch is to be used with an
alarm system, connect this wire with
diode.
To: White/Black Wire /
Negative safety
To: Alarm instant
trigger Blue wire
Hood Pin Switch
Diode
Diode
Important! This connection is a safety wire and must be connected as shown and
tested as specifiled. Failure to do so may result in personal injury or property damage.
See detail of wiring in the following diagram. This wire may also be used if the vehicle
brake light circuit switches ground to the brake lights. An isolation diode must be
used for ground switched brake light circuits and must be connected to the output of
the brake switch.
H6/21 Orange wire (-) 200mA Grounded Output When Armed
This wire will become grounded when the alarm is armed. The current capacity of
this wire is 200mA. This output can control starter disable, when an intrusion is
detected and the system is triggered. The vehicles prevent from any unauthorized
starting.
87
87a
85
30
86
IN4003 Diode
H10/20: ORANGE wire
from control module
“Start”
“On”
Purple wire
X
Cut
Yello wire
White wire
“Acc”
“Off”
Starter
H1/1 VIOLET wire (Starter output)
form Heavy Gauge wire harness
Red wire to
Ignition Switch
H6/22 Black / Red Wire (-) 200mA Timer Control Channel 5
(See Alarm Feature C 6 Programming) This wire is built-in user -programmable timer output
provides a ground through this wire. Press the transmitter and buttons at the same time.
You may program the built-in timer to send a ground signal for any time interval between 1
second and 2 minutes. For instance, this timer output may be used to turn on the headlight with
the remote control. Also on certain BMW, Mercedes Benz, Jaguar and Volkswagen cars, you
can use this unique timed output to allow remote closure of all power window and sunroof
without the need for an external module!
H4. 3 PIN DOOR LOCK CONNECTOR: (Maximum 500mA Output)
Blue Wire
Green Wire
( - ) Lock Pulse
( + ) Unlock Pulse
( - ) Unlock Pulse
(+) Lock Pulse
Red(not used)
NEGATIVE TRIGGER DOOR LOCK SYSTEM
Red (not used)
Blue Wire Door Unlock
Green Wire Door Lock
Locking
Master
Switch
To Exiting
Door Lock Relay