Auto Page C3-RS1100 Automobile Alarm User Manual


 
C3 RS1100REV. A
28
b. Press button on the transmitter to set proper “Start Timer”. The chirp & LED
pause will confirm entry. (Increase “Start Timer ” is necessary.)
c. Repeat steps 1 4.
Timer Checking Type
1. Turn the Ignition 'switch ‘ON/OFF’ 3 TIMES and stay in OFF position.
2. Push the Valet switch 11 times and hold it on the 11
th
push until five chirps with a
long chirp is hearing then release the valet switch.
3. Press the transmitter and buttons at the same time to set the “Timer
Checking Type”. [3] LED flashes, [3] chirps to confirm this setting
Once you complete step 3, you can adjust and test “Start Timer” as below:
START TIMER PROGRAMMING: (TEST and ADJUST)
While the system is in Start Feature “E” programming mode,
1. Press the button once on the transmitter to start the vehicle.
2. If everything goes well:
a. Press the ' button once on the transmitter to stop engine running. You have
been completed this programming successfully.
b. Press button on the transmitter to exit the program mode. There will be 3 long
chirps & 3 parking light flashes for confirmation.
3. If the crank time is too long, (Engine already successfully running, but still cranks):
a. Press the button once on the transmitter to stop engine running.
b. Press the button on the transmitter to set proper “Start Timer”. The chirp & LED
pause will confirm entry. (Decrease “Start Timer” is necessary.)
c. Repeat the step1 4.
4. If the crank time is too short, (Engine not running, crank stopped before starting):
a. Press the button once on the transmitter to stop engine running.
b. Press button on the transmitter to set proper “Start Timer”. The chirp & LED
pause will confirm entry. (Increase “Start Timer ” is necessary.)
c. Repeat the step1 4.
TEST MODE
In this test mode, this system can test the Zone 2 (Instant ground trigger), the Zone 3
(Door trigger), and the Zone 1 & Zone 4 (2 stage shock sensor) sensitivity. The
installer can save time to test the 2-stage shock sensor sensitivity and sensor without
using the traditional arming/disarming procedures to test the sensors.
Enter:
1. Turn the Ignition 'switch ‘ON/OFF’ 3 TIMES and stay in OFF position.
2. Push the Valet switch 11 times (holding in on the 11
th
) until five chirps with one long
chirp is heard then release the valet switch. You are now in the Start feature ‘”E”
programming mode.
a. Test the Zone 2 / Instant Ground Trigger & Zone 3 / Door Trigger:
Press and release the transmitter and buttons at the same time once. [1]
LED flash, [1] siren/horn chirp to indicate your are in Zone 2 / instant ground
trigger and Zone 3 / Door trigger test mode.
Trigger sensor Siren chirps
Zone 2 / Instant Ground trigger (H6/17 Blue wire) 2
Zone 3 / Door trigger (H6/15 Green or H6/19 Violet wire) 3