Sanyo XH2442 Automobile Accessories User Manual


 
22
22
2
K
29
S4359146
3-17. Shaping the Tubing
(1) Shape the refrigerant tubing so that it can easily
go into the hole. (Fig. 3-47)
(2) Push the wiring, refrigerant tubing and drain hose
through the hole in the wall. Adjust the indoor unit
so it is securely seated on the wall fixture.
(3) Carefully bend the tubing (if necessary) to run
along the wall in the direction of the outdoor unit
and then insulate to the end of the fittings. The
drain hose should come straight down the wall to
a point where water runoff will not stain the wall.
(4) Connect the refrigerant tubing to the outdoor unit.
(After performing a leak test on the connection,
insulate it with insulating tape. (Fig. 3-48)) Also,
refer to Section 10-5. “Connecting Tubing be-
tween Indoor and Outdoor Units”.
(5) Assemble the refrigerant tubing, drain hose and
inter-unit wiring as shown in Fig. 3-49.
0954_T_I
Cover
Refrigerant
tubing
Inter-unit
wiring
Drain hose
Fig. 3-47
0955_T_I
Insulating
tape
(1) Shape the narrow refrigerant tube and the drain
hose in the desired direction so that they can
easily go into the wall hole. (Fig. 3-50)
(2) Push the wiring, narrow tube, and drain hose
through the hole in the wall.
(3) Bend the tubing (if necessary) to run along the
wall in the direction of the outdoor unit, then tape
as far as the fittings. The drain hose should come
straight down the wall to a point where runoff
won't stain the wall.
(4) Hang the indoor unit on the wall fixture. (Fig. 3-51)
(5) Install the mounting plate to secure the indoor unit
solidly to the wall. The plate can be positioned in
either of the 2 ways shown. (Fig. 3-52)
1367_T_I
Mounting plate
Screws
Or
Fig. 3-52
Fig. 3-48
1098_T_I
Refrigerant tubing
Inter-unit wiring
Drain hose
Fig. 3-49
1365_T_I
Narrow
tube
Drain hose
Fig. 3-50
1366_T_I
Wall
Wall fixture
Indoor
unit
KH2442
KH3642
Fig. 3-51