Mitsubishi Electronics FR-F740EC/E1 Automobile Accessories User Manual


 
23
MITSUBISHI ELECTRIC
FR-F 740 EC/E1
52
DU/PU main display data selection
0/5/6/8–14/17/20/23/
24 / 25 / 50–57 / 100
0
54
CA terminal function selection
1–3/5/6/8–14/17/21/24/50/52/53
1
55
Frequency monitoring reference
0–400 Hz 50 Hz
56
Current monitoring reference
0–500 A /
0–3600 A
Rated current
57
Restart coasting time
0 / 0.1–5 s / 9999 /
0 / 0.1–30 s / 9999
9999
58
Restart cushion time
0–60 s 1 s
59
Remote function selection
0/1/2/3 0
60
Energy saving control selection
0/4/9 0
65
Retry selection
0–5 0
66
Stall prevention operation reduction starting frequency
0–400 Hz 50 Hz
67
Number of retries at alarm occurrence
0–10 / 101–110 0
68
Retry waiting time
0–10 s 1 s
69
Retry count display erase
00
70
Special regenerative brake duty
0–10% 0%
71
Applied motor
0/1/2/20 0
72
PWM frequency selection
0–15 /
0–6 / 25
2
73
Analog input selection
0–7 / 10–17 1
74
Input filter time constant
0–8 1
75
Reset selection/disconnected PU detection/PU stop selection
0–3 / 14–17 / 100–103 / 114–117
14
76
Alarm code output selection
0/1/2 0
77
Parameter write selection
0/1/2 0
78
Reverse rotation prevention selection
0/1/2 0
79
Operation mode selection
0–4/6/7 0
80
Motor capacity (simple magnetic flux vector control)
0.4–55 kW / 9999 /
0–3600 kW / 9999
9999
90
Motor constant (R1)
0.4–50 / 9999 /
0–400 m/ 9999
9999
100
V/f1 (1st frequency)
0–400 Hz / 9999 9999
101
V/f1 (1st frequency voltage)
0–1000 V 0
102
V/f2 (2nd frequency)
0–400 Hz / 9999 9999
103
V/f2 (2nd frequency voltage)
0–1000 V 0
104
V/f3 (3rd frequency)
0–400 Hz / 9999 9999
105
V/f3 (3rd frequency voltage)
0–1000 V 0
106
V/f4 (4th frequency)
0–400 Hz / 9999 9999
107
V/f4 (4th frequency voltage)
0–1000 V 0
108
V/f5 (5th frequency)
0–400 Hz / 9999 9999
109
V/f5 (5th frequency voltage)
0–1000 V 0
117
PU communication station
0–31 0
118
PU communication speed
48 / 96 / 192 / 384 192
119
PU communication stop bit length
0/1datalength8;10/11datalengthe7 1
120
PU communication parity check
0/1/2 2
121
Number of PU communication retries
0–10 / 9999 1
122
PU communication check time interval
0–999.8 s / 9999 9999
123
PU communication waiting time setting
0–150 ms / 9999 9999
124
PU communication CR/LF presence/absence selection
0/1/2 1
125
Terminal 2 frequency setting gain frequency
0–400 Hz 50 Hz
126
Terminal 4 frequency setting gain frequency
0–400 Hz 50 Hz
127
PID control automatic switchover frequency
0–400 Hz / 9999 9999
128
PID action selection
10 / 11 / 20 / 21 / 50 / 51 / 60 / 61 10
129
PID proportional band
0.1–1000% / 9999 100%
PARAMETER