7. Projector Status
• Lamp run time : expressed in hours. Time lamp is running since first start up of this lamp.
• Lamp strikes : number of strikes since first start up of the lamp.
• Active cooling Red (active - not active) : when active, Peltier cooling is activated for Red DMD.
• Active cooling Green (active - not active) : when active, Peltier cooling is activated for Green DMD.
• Active cooling Blue (active - not active) : when active, Peltier cooling is activated for Blue DMD.
• Waterflow : checks if waterflow is possible. See also location waterflow switch.
Image 7-3
Waterflow switch location
7.3 Status overviews
Overview
• Voltage statuses
• Temperature statuses
• Fan statuses
7.3.1 Voltage statuses
Status overview
When one of the voltages are out of specification, the voltage indication will be red.
46
R5976790 COMMUNICATOR 09/07/2004