Appendix A Troubleshooting
ATCA-C110/1G Installation and Use Manual
87
REVIEW COPY
RTM gets reset. Super capacitor is drained if the
board has not been powered on
for a sufficient duration (more
than 8 hours).
Power on the board and reconfigure the RTM.
Wait for at least ten minutes for the super
capacitor to charge.
Board hangs or becomes
unstable
Inadequate airflow Check if the airflow is adequate see Appendix C,
Thermal Validation.
Application software does
not work
Memory ranges of system and
peripheral boards do not match.
Change application software so that memory
ranges match I/O cards and host.
Not enough disk capacity on
mass storage device.
Add disk capacity.
Used I/O ranges do not match. Change application software so that I/O ranges
match I/O cards and host.
Connected devices do not
work
Device defect Replace device
Device not connected to power
supply.
Connect device to power supply.
Wrong board configuration, faulty
switch setting.
Configure the board correctly for the respective
device.
Devices are disabled. Configure board correctly.
Problem Possible Reason Solution