DCM-2 SERIAL INTERFACE Command Error Codes
Code
2
3
4
5
6
9
10
14
32
64
Description
Invalid selection
Value too big
Value too small
Data length error
General error
Process too high
Process too low
Span too small
Busy
Not implemented
Information
Displayed when an unknown command
has been entered.
Displayed when an entered numeric
value exceeds expected parameters.
Displayed when an entered numeric
value is less than expected parameters.
Displayed when the wrong number of
arguments is entered.
Displayed when a combination of
circumstances prevents a better
description of the error.
Displayed when the entered value
exceeds acceptable parameters when
calibrating a 0% value.
Displayed when the entered value is
less than acceptable parameters when
calibrating a 100% value.
Displayed when entered values for a 0%
point and a 100% point are too close.
Displayed when a memory store is
requested and another memory store is
already in process.
Displayed when an entered command is
dened, but cannot be implemented.
Command Error Codes
When an error is encountered using the serial commands, an "ERROR XX" message is returned. The
table below provides a description of the error codes ("XX").