Beck, R&J 11-1_9 Automobile Parts User Manual


 
72
DCM-2 SERIAL INTERFACE Commands
Note: For specic information on the following functions, see the HART interface section of the manual.
Command
torqconst n
torqenable n
Description
Assigns the count value to be
associated with the torque span. This
number is unique to each drive.
Enables or disables the torque
measurement feature of the drive.
Argument n and Information
n = the torque span value in counts.
This number is determined during
manufacture and is noted on a tag
afxed to the drive body within the
electronics compartment.
n = "0" (disabled) or "1" (enabled).
Torque Sensing Commands (con't)
Command
signals
stat
tempf
torq
Description
Displays the present Position signal
of the drive in volts and the Demand
signal in milliamps.
Displays information on the status of
the drive, including:
Time / Date
Demand (% and settings)
Position (% / inches)
Error (%)
Stepsize (inches / %)
Deadband (inches / %)
Motor Status
Run Time
Line Frequency
Starts (ext./ret./total)
Reversals/Stalls
Overloads
Positive & Negative Peak Load (%)
Positive & Negative Peak Torque
(% / inches)
Extend and Retract Inhibit Setting
Alarms
Displays measured temperatures in the
drive (°F.):
Low extreme
Present temperature
High extreme
Displays the drive's present torque
measurement as a percentage of rated
torque.
Argument n and Information
No argument.
No argument.
No argument.
No argument.
Diagnostic and Information Commands