Polaris SL2 Automobile User Manual


 
72
MAINTENANCE
Battery
Battery Charging
The following battery charging instructions apply only to the installation of a sealed battery.
Read all instructions before proceeding with the installation of this battery.
The sealed battery is already filled with electrolyte and has been sealed and fully charged at
the factory. Never pry the sealing strip off or add any other fluid to this battery.
The single most important thing about maintaining a sealed battery is to keep it fully
charged. Since the battery is sealed and the sealing strip cannot be removed, you must use a
voltmeter or multimeter to measure DC voltage.
WARNING! An overheated battery may explode, causing severe injury or death. Always watch
charging times carefully. Stop charging if the battery becomes very warm to the touch. Allow it to cool
before resuming charging.
For a refresh charge, follow all instructions carefully.
1. Check the battery voltage with a voltmeter or multimeter. A fully charged battery will
register 12.8 V or higher.
2. If the voltage is less than 12.8 volts, recharge the battery at 1.8 amps until battery voltage
is 12.8 or greater.
3. When using an automatic charger, refer to the charger manufacturer's instructions for
recharging.
4. When using a constant current charger, use the guidelines below. Always verify battery
condition before and 1-2 hours after the end of charging.
State of
Charge
Voltage
(DC)
Action
Charge Time
(Using constant current
charger @ standard amps
specified on top of battery)
100% 12.8-13.0 volts None, check again
in 3 months
None required
75%-100% 12.6-12.8 volts May need slight
charge, if no
charge given,
check in 3 months
3-6 hours
50%-75% 12.3-12.6 volts Needs charge 5-11 hours
25%-50% 12.0-12.3 volts Needs charge At least 13 hours
0%-25% 12.0 volts or less Needs charge At least 20 hours