Furuno GP-150-DUAL GPS Receiver User Manual


 
10. INSTALLATION
10-15
Setting DATA 4 to Data Output
1) Press MENU ESC, 9 and 5 to show the DATA4 I/O SETUP menu.
DATA 4 I/O SETUP 1/2
To Next Page
ENT : Enter MENU : Escape
Appears only when external
DGPS receiver is used.
DATA 4. Level RS232C RS422
Data Out Com. DGPS
: Select
DATA4 I/O SETUP menu
2) Press
to select DATA 4. Level.
3) Press
or to select level of external equipment; RS-23C or RS422.
4) Press the CU/NU ENT key.
5) Press
or to select Out.
6) Press
to go to the next page to show the DATA I/O SETUP <Out> menu.
To Previous Page
Talker ID GP LC DE
Output Data (00-90 sec) 98%
DATA 4 I/O SETUP <Out> 2/2
MENU : Escape
ENT : Enter
Data Fmt. V1.5 V2.0 IEC
1. AAM:00 APA:00 APB:04 BOD:00
2. BWR:00 BWW:00 GGA:00 GLL:01
3. RMB:01 RMC:00 VTG:01 WCV:00
4. WNR:00 WPL:00 XTE:00 ZDA:01
5. GNS:00 GBS:01 Rnn:00 RTE:00
DATA4 I/O SETUP <Out> menu
7) Follow "DATA 1 output setting" from step 2.