Furuno GP-150-DUAL GPS Receiver User Manual


 
8. MENU SETTINGS
8-7
2) Press to select Data Fmt.
3) Press
or to select NMEA 0183
(V1.5 or V2.0) or IEC 61162-1.
4) Press the NU/CU ENT key. Talker ID
appears in reverse video.
5) Press
or to select GP, LC or DE.
6) Press the NU/CU ENT key.
7) Enter Tx interval for each output data
sentence in line 1. Tx interval is available
in 00, 01, 02, 03, 04, 05, 06, 10, 15, 20,
30, 60 and 90 (seconds).
8) Press the NU/CU ENT key.
9) Enter Tx interval for each output data
sentence in lines 2 through 5. Press the
NU/CU ENT key after setting each line.
For detailed information about Tx interval
see the chapter on installation. However, the
Tx interval settings entered by the installer of
the equipment should not be changed unless
absolutely necessary.
BWC and WNC are for great circle
navigation and BWR and WNR are for
rhumb line navigation. However, all output
data are calculated by rhumb line.
When the external equipment cannot display
data input from the GP-150-DUAL correctly,
the rate of operation should be lowered.
For example, set a rate of operation less
then 60% for the Temperature Indicator
TI-20.
DATA 3 output setting
The DATA 3 connector can output IEC
61162-1/NMEA 0183 data or log pulse. For
NMEA 0183, IEC 61162-1 the same data
output by DATA 1 is output from DATA 3.
For log pulse, select 200 or 400 pulse per
second depending on the device connected.
1) Press MENU ESC, 9 and 3.
2) Press
to select DATA 3 or Log Pulse.
3) For log pulse, press
or to select
log pulse of external equipment; 200 ppm
or 400 ppm.
4) Press the NU/CU ENT key twice.
Setting DATA 4 to data output
The DATA 4 port connects to a personal
computer, DGPS receiver or YEOMAN
equipment.
1) Press MENU ESC, 9 and 5. The DATA 4
I/O SETUP (1/2) menu appears.
DATA 4. Level RS422
Data Out Com. DGPS
To Next Page
DATA 4 I/O SETUP 1/2
MENU : Escape
ENT : Enter
: Select
DATA 4. Level
RS232C
Figure 8-9 DATA 4 I/O SETUP menu (1/2)
2) Press
to select Level.
3) Press
or
to select level of external
equipment; RS232C or RS422.
4) Press the NU/CU ENT key.
5) Press
or
to select Out.
6) Press
to select To Next Page. The
DATA 4 I/O SETUP (2/2) menu appears.