Furuno BB FAR28x7 Radar Detector User Manual


 
FURUNO
FAR-21x7(-BB)/28x7 SERIES
SP - 3 E3519S01L-M
PM-51 (S-band)
1. Frequency range 3020 to 3080 MHz
2. Input power Min. -5 dBm, Max. +15 dBm
3. Power output (2
nd
pulse max output) -15 dBm
4. Power output (2
nd
pulse min output) -35 dBm
5. Steps levels (1
st
pulse to 2
nd
pulse) 9.0 to 11.0 dB
6. POWER SUPPLY
1. Display unit 24 VDC or 115/230 VAC, 1ø, 50/60 Hz
FAR-21x7: 24 VDC, 2.3 A; 100-230 VAC, 0.7A (100 V)
FAR-28x7: 24 VDC, 3.2 A; 100-230 VAC, 0.9 A (100 V)
440 VAC, 1 ø, 50/60 Hz with optional transformer RU-1803
2. Processor unit FAR-2117/2817/2117-BB:
24VDC: 7.6A
1
/8.5A
2
, 100-115 VAC: 2.6A
1
/3.0A
2
,
220-230 VAC: 1.6A
1
/1.7A
2
FAR-2127/2827/2127-BB:
24 VDC: 8.8A
1
/9.7A
2
, 100-115 VAC: 3.0A
1
/3.4A
2
,
220-230 VAC: 1.8A
1
/1.9A
2
1:
24 rpm,
2:
42 rpm
FAR-2827W:
3.2A (100-115 VAC), 1.6A (220-230 VAC)
FAR-2157/2157-BB/2167DS/2167DS-BB/2137S/2137S-BB/2837S/
2837SW:
3.0A (100-115 VAC), 1.5A (220-230 VAC)
3. Antenna unit X-band: 24 VDC, 4A, 200/220 VAC, 2A, 3
ø, 50/60 Hz
S-band: 200/220/380/440 VAC
115/230 VAC, 1ø, 50 or 60 Hz
Antenna voltage input (100 kt) Model
200 VAC,
ø3, 50 Hz,
220 VAC,
ø3, 60 Hz
380 VAC,
ø3, 50 Hz,
440 VAC,
ø3, 60 Hz
220 VAC,
ø3, 50 Hz,
(HSC)
220 VAC,
ø3, 60 Hz,
(HSC)
440 VAC,
ø3, 60 Hz
(HSC)
FAR-2137S(BB) 3.0 A 1.5 A 3.5 A 3.5 A 1.7 A
FAR-2167DS(BB) 3.0 A 1.5 A - - -
FAR-2837S 3.0 A 1.5 A 3.5 A 3.5 A 1.7 A
FAR-2837SW 3.0 A 1.5 A - - -
FAR-2137SW 3.0 A 1.5 A - - -
4. Console 115/230 VAC, 1ø, 50/60 Hz, 440 VAC, 1ø, 50/60 Hz with optional
transformer RU-1803
7. ENVIRONMENTAL CONDITIONS
1. Ambient temperature (Complies with IEC 60945)
Indoor units -15°C to +55°C
Antenna unit -25°C to +55°C (storage +70°C)
2. Relative humidity 95% at 40°C
3. Waterproofing Antenna unit: IPX6 (IEC 60529)
Indoor units: IPX0 (IEC 60529)
4. EMC Full compliance with IEC 60945 Ed. 4
(to 2 GHz cabinet radiation)