6 - 6
– +
ELEC
IGNITION SYSTEM
2. Inspect:
• Source coil 1 resistance
Out of specification → Replace.
3. Inspect:
• Source coil 2 resistance
Out of specification → Replace.
Tester (+) lead
→
Brown lead
1
Tester (–) lead
→
Green lead
2
Source coil 1
resistance
Tester selector
position
720 ~ 1,080
Ω
at
20 °C (68 °F)
Ω
×
100
Tester (+) lead
→
Pink lead
1
Tester (–) lead
→
Black lead
2
Source coil 2
resistance
Tester selector
position
44 ~ 66
Ω
at
20 °C (68 °F)
Ω
×
10
W
R
Br
G
P
B
2
1
2
1
2
1
W
R
Br
G
P
B
2
1
NEUTRAL SWITCH INSPECTION
1. Inspect:
• Neutral switch conduct
No continuity while in neutral → Replace.
Continuity while in gear → Replace.
EC628000
CDI UNIT INSPECTION
Check all electrical components. If no fault is
found, replace the CDI unit. Then check the
electrical components again.
Tester (+) lead
→
Sky blue lead
1
Tester (–) lead
→
Ground
Sb
1
Ground
Tester selec-
tor position
NEUTRAL
Ω
×
1
IN GEAR
– +
Ω×1
1
Sb