MON – RXBUF (0x0A 0x07)
It periodically polls the status of receiver buffer.
Header ID Data Length Data Checksum
0xB5 0x62 0x0A 0x07 16 See below CK_A CK_B
Data
Offset bytes Format Descriptions Notes
0 U2[4] Number of pending bytes in
receiver buffer on each target
(bytes)
8 U1[4] Maximum usage receiver buffer
for the last system-monitoring
period of each target
12 U1[4] Maximum current usage
receiver buffer for each target