ENGINE AND PERIPHERALS
Specifications
10
10-36
FITTING THE ENGINE TO SUPPORT Mot. 792-03
AND THE THREE RODS A, B AND C
Engines of all types
Remove the intake and exhaust manifolds,
The rods (A), (B) and (C) are mounted on the cylinder
block so that they fit into the holes (1, 8, 17) on the
plate.
SAFETY PRECAUTIONS
Turbocharger engine
After performing an operation on the engine that
involves disconnecting the oil gallery, it is essential to
reprime the turbocharger oil circuit, ensuring that the
following conditions are respected:
– connect the oil return and attach it using a new bolted
clamp,
– fill up the turbo with engine oil through the inlet
opening (A),
– run the starter motor to reprime the turbocharger oil
circuit, until the oil begins to escape from the
turbocharger inlet opening,
– reconnect the turbocharger inlet pipe,
– run the engine at idle speed so that the circulation of
oil in the turbocharger is reestablished.
SAFETY PRECAUTIONS WHEN STOPPING THE
ENGINE
Let the engine run at idle speed for 30 seconds
and then switch off the ignition.
Do not rev the engine to avoid starting the
turbocharger. If this occurs, the turbo may run by
inertia without lubrication when the ignition is switched
off and there is a risk that the turbine shaft will grate.
90749R1