11A-6-4
INSTALLATION SERVICE POINTS
"
A
A
WATER PIPE / O-RING INSTALLATION
(1) Wet the O-ring (with water) to facilitate assembly.
Caution
D
Keep the O-ring free of oil or grease.
"
B
A
SEALANT APPLICATION TO THERMOSTAT
HOUSING
Specified sealant:
Mitsubishi Genuine Part No. MD970389 or
equivalent
NOTE
(1) Be sure to install the housing quickly while the sealant
is wet (within 15 minutes).
(2) After installation, keep the sealed area away from
the oil and coolant for approx. 1 hour.
"
C
A
SEALANT APPLICATION TO ENGINE COOLANT
TEMPERATURE GAUGE UNIT
Specified sealant: 3M ATD Part No. 8660 or equivalent
"
D
A
SEALANT APPLICATION TO ENGINE COOLANT
TEMPERATURE SENSOR
Specified sealant:
3M Nut Locking Part No. 4171 or equivalent
AddedPWEE9616-A
E
Aug. 1998Mitsubishi Motors Corporation
6EN0594
Water pipe
O-ring
6EN1168
3 mm diameter
bead sealant
9EN0092
9EN0091