I
37
MANUALGEARBOX
DEFENDER
4.
Drive out quadrant
roll
pin.
5.
Move selector shaft forward to remove
quadrant.
n
5
ST2180M
2.
Using service
tool
18G
705
and
18G 705
-
1A
withdraw the oil seal collar.
&-
/U
18G 705
3.
Remove the fifth gear extension housing.
4.
Secure the centre plate
to
the gearcase with
EXTENSION
HOUSING
.
two
8
x
35" bolts.
1.
Remove snap ring retaining oil seal collar.
ST2316M
2
I
OVERHAUL