Volkswagen 01M Automobile Parts User Manual


 
AUTO TRANS DIAGNOSIS - 01M
Article Text (p. 58)
1996 Volkswagen Golf
For Volkswagen Technical Site
Copyright © 1998 Mitchell Repair Information Company, LLC
Thursday, August 19, 1999 11:28PM
Valve Body Bolts .................................. 44 (5)
Valve Body Conductor Strip Bolt .................. 89 (10)
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
TRANSMISSION SPECIFICATIONS
TRANSMISSION SPECIFICATIONS
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
Application In. (mm)
Clutch Clearance
Apply Clutches ..................................... (1)
Brake Clutches
2nd-4th ..................... (2) .060-.068 (1.50-1.74)
Reverse ........................... .047-.071 (1.2-1.8)
Gear & Shaft End Play
Planetary Carrier .................. .009-.014 (.23-.37)
1st-3rd To Reverse Apply Clutch ... .019-.047 (.50-1.20)
Turbine Shaft ..................... .019-.047 (.50-1.20)
(1) - Assembled clutch clearance is not available.
(2) - See TRANSMISSION under TRANSAXLE REASSEMBLY.
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
TECHNICAL SERVICE BULLETINS
SHIFTING ERRATIC, HARSH OR DELAYED
1993-On Cabrio, Golf, GTI, Jetta & Passat (Group 01, TSB No.
97-01, 1-8-97)
Transaxle may shift erratic, harsh or hold shifts too long
(delayed upshifts) with no trouble codes stored in memory. This
condition is normally caused by improper throttle angle setting. If
shifting quality is a concern, perform THROTTLE ANGLE SETTING
procedure.
NOTE: On a newly installed TCM, basic settings must be set prior
to performing the following procedure. Basic settings can be
set with Scan Tool (VAG 1551) using Function "04", Display
"OOO".
Throttle Angle Setting
1) Connect scan tool. Turn ignition on. Press "1" to select
RAPID DATA TRANSFER. Enter address word 02 "TRANSMISSION ELECTRONICS"
and advance until "SELECT FUNCTION XX" appears in scan tool display.
2) Press buttons "0", then "8" to select function 08 "READ
MEASURING VALUE BLOCK". Press "Q" button to confirm input. Press "Q"
button once more, then enter group No. 001. Press "Q" button to
confirm input.
3) Print screen. While observing scan tool display, slowly
press accelerator pedal until display reads 25 percent. DO NOT release