6 F 8 A 0 9 3 4
Switch operation
Display example
Description
Push to move the cursor to the
desired digit and push to change the
number of the digit.
When you push , a message appears
to confirm whether the setting is OK or not.
If OK, push . If you want to redo the
setting, push .
Pushing cancels the setting operation
and exits the setting screen.
Note: If you try to set a value exceeding 25.0%, HIGH OVER SPEC error appears and the
value returns to the previous value. Set a value once again.
8.2.10 Damping Constant
The damping constant is used to moderate output fluctuations. (The larger the damping constant, the more
the output is averaged. But the response to an input change will be slower.) The damping constant can be
set as follows:
The damping constant is set for 0.0 sec, 0.5 sec and 1 to 200 sec (in increments of 1 second)
Note: 0.0 sec setting will work as equal to 0.1 sec damping constant.
Set 1 sec or more for normal operation.
If you set a value exceeding 200s, it is forcibly changed to 200s before data is written.
Proceed as follows to check or change the damping constant.
Shown below is an example of changing the damping constant from 5.0s to 10s.
Switch operation
Display example
Description
Select "DAMPING" from the setting item
selection menu.
The currently set damping constant (5.0s in
this example) appears.
Then push .