LF516 Detector Specifications
Meter size: 25, 40, 50, 80, 100mm
Fluid pressure: -0.1 ~ 2MPa
Connection flange standard: See Table 15.2 Type Specification Code
Heat shock resistance for ceramic tube detector
Cooling: ΔT 100 /0.5s
Heating: ΔT 150 /0.5s
Note: Meaning that the ceramic tube detector withstands the shock of
sudden cooling (temperature difference 100 or less per 0.5 seconds)
at the cooling side.
or sudden heating (temperature difference 150 or less per 0.5 seconds)
at the heating side.
Principle materials
Case – Stainless steel
Lining – Ceramic
Grounding rings – 316 stainless steel (standard)
See Type Specification Code for optional materials and other related information.
Structure: IP68 Watertight