PowerTec OMRG25204 Automobile Parts User Manual


 
Engine Operating Guidelines
RG,RG34710,5555 –19–27JUL06–1/1
Auxiliary Gear Drive Limitations
RG7634A –UN–22JAN99
Auxiliary Gear Drive
A—Auxiliary Gear Drive
IMPORTANT: When attaching an air compressor,
hydraulic pump, or other accessory to
be driven by the auxiliary gear drive (A)
(engine timing gear train at front of
engine), power requirements of the
accessory must be limited to values
listed below:
30 kW (40 hp) Continuous Operation at 2500 rpm
37 kW (50 hp) Intermittent Operation at 2500 rpm
RG,RG34710,5556 –19–27JUL06–1/1
Generator Set (Standby) Applications
To assure that your engine will deliver efficient standby
operation when needed, start engine and run at rated
speed (with 50%—70% load) for 30 minutes every 2
weeks. DO NOT allow engine to run extended period of
time with no load.
15-9
110306
PN=53