PowerTec OMRG25204 Automobile Parts User Manual


 
Service as Required
OURGP11,000000D –19–18OCT06–6/7
RG8069 –UN–23NOV97
DENSO Fuel Injection Pump Shown
On DENSO and Motorpal in-line pumps:
1. On DENSO pump shown, unscrew hand primer on fuel
supply pump until it can be pulled by hand.
2. Open fuel filter port plug.
3. Operate the hand primer until a smooth flow of fuel,
free of bubbles, comes out of the filter plug hole.
4. Simultaneously stroke the hand primer down and close
the filter port plug. This prevents air from entering the
system. Tighten plug securely. DO NOT overtighten.
IMPORTANT: Be sure hand primer is all the way
down in barrel before tightening to
prevent internal thread damage.
5. On DENSO pump shown, lock hand primer in position.
OURGP11,000000D –19–18OCT06–7/7
RG7725 –UN–08JAN97
Fuel Line Connection
At Fuel Injection Nozzles
1. Move the engine speed control lever to half throttle
position. On engines equipped with electronic fuel
shut-off solenoid, energize solenoid.
2. Using two open-end wrenches, loosen fuel line
connection at injection nozzle as shown.
3. Crank engine over with starter motor, (but do not start
engine), until fuel free from bubbles flows out of
loosened connection.
4. Retighten connection to 27 N•m (20 lb-ft).
5. Repeat procedure for remaining injection nozzles (if
necessary) until all air has been removed from fuel
system.
If engine still will not start, see your authorized
servicing dealer or engine distributor.
45-14
110306
PN=119