10.12
ELECTRICAL
CHARACTERISTIC PARAMETER UNIT NOTE
Operating Temperature -40 to +55 C
Ambient temperatures at which module
should remain within specified limits
Storage Temperature -50 to +85
C
Ambient temperatures which should
have no adverse effects
on module operation
CHARACTERISTIC MIN TYP MAX UNIT NOTE
Battery Voltage 7 14.4 16 Vdc PDM functions will operate over this range
Batt. Quiescent Current 2 mA Min. draw from battery with key off
REGULATOR
Regulator Voltage 14.1 14.4 14.8 Vdc
Regulator Output 18 Adc Max. total DC amperage available from regulator
Minimum Battery Voltage 2 Vdc
Min. voltage required on RUN for
regulator to begin operation
Alternator Coil 1 Resistance
14.7k
15k
15.2k
Ohm
Resistance between alternator signal and ground
Only on this designated alternator signal
BAT_PROT OUTPUT
Output Current
8
Amp Nominal Continuous output current
Limit
9
11
20
Amp Current level that will cause turn off after delay
Time Delay 100
150
mSec Time above limit until SSCB trips
Voltage 5.5 Vdc Min Battery voltage for BAT_PROT to remain on
ACC_PWR OUTPUT
Output Current 10 25 Amp Max. continuous current
Nominal Current 26 Amp
Current above which the output will shut off after
15 - 25 seconds
Overload Current
13
16 19 Amp
Current above which the output will shut off after
1.5 - 2.5 seconds
Peak Current - Hardware
31
50
65
Amp
Initial peak short circuit current limit above which the device
will current limit then quickly shut down
Power Off Delay
7
10
13
Sec Delay after run switch is turned off
LIGHTS OUTPUT
Output Current 18 Amp MAX Continuous Current
Current Limit
40
65
65
Amp
Current limit above which device will shut down within
thermal shutdown time
Repetitive Short Circuit
Limit
65 Amp Current level that will cause turn off and on after delay
Inrush Time
50
100
500
mSec Inrush time delay
STARTER OUTPUT
Current 6 Amp Current capability of the STARTER output
TRANS
Park Voltage
118
490 870 mVdc Current capability of the output
Neutral Voltage
1.73 2.11
2.48 Vdc Current capability of the output
REVERSE POLARITY PROTECTION
Battery Reverse Current 1.8
2
mA Max reverse leakage current when connected in reverse
Reverse Bias Voltage 2
-55
Vdc Absolute maximum reverse voltage before device breakdown.