Firstech, LLC. RF-2W900FM-5PT Automobile Alarm User Manual


 
CM6000 Install Guide
Alarm and Starter System
www.firstechonline.com | www.compustar.com
Copyright 2009 Firstech, LLC.
Page 17
Connector 6 (CN6), 4-Pin (RS 232 Data Port)
This connector is used for updating control modules via www.rstechonline.com. You must also use this port to
ash Blade bypass modules. This port provides simple connectivity of Fortin and iDataLink bypass modules.
Connector 7 (CN7), 3-Pin (Pre-wired Valet/Programming Switch)
Pin 1 Gray/Black - Negative (-) ground.
Pin 2 Gray – 3V positive (+) L.E.D. output.
Pin 3 Gray – Negative (-) output.
Connector 8 (CN8), 2-Pin (Pre-wired Thermister)
Plug optional thermister into this connector to monitor the vehicle’s temperature. It used in conjunction with
Timer Start features along with displaying temperature on two-way LCD’s. To use Timer Start features review
Option Group 2. IMPORTANT: Thermister plugs are blue 2 pin connectors on the CM6 series but old white
plug Thermisters will still work.
Pin 1 Black - Thermister
Pin 2 Black/White - Thermister
Connector 9 (CN9), 4-Pin to 4-Pin or 6-Pin (Pre-wired Antenna Cable)
Connect your antenna cable to this port. You can only use 4 to 4 pin or 4 to 6 pin antenna cables. 6 to 6 Pin an-
tenna cables do not work. Do not use both Connector 9 and Connector 10 at the same time.
Pin 1 Yellow - RX input. This wire receives the signal from remote.
Pin 2 White - TX output. This wire transmits the signal to remote.
Pin 3 Red – Constant 12V positive (+) output.