3 - 16
CHK
ADJ
ADJUSTING THE EXHAUST GAS VOLUME
EAS00869
ADJUSTING THE EXHAUST GAS VOLUME
NOTE:
_
Be sure to set the CO density level to stan-
dard, and then adjust the exhaust gas volume.
1. Turn the main switch to “OFF” and set the
engine stop switch to “”.
2. Simultaneously press and hold the
“SELECT” and “RESET” buttons, turn the
main switch to “ON”, and continue to press
the buttons for 8 seconds or more.
NOTE:
_
“dIAG” appears on the odometer/fuel reserve
tripmeter/tripmeter 2 LCD.
3. Press the “SELECT” button to select the CO
adjustment mode “Co” or the diagnostic
mode “dIAG”.
4. After selecting “Co”, simultaneously press
the “SELECT” and “RESET” buttons for 2
seconds or more to execute the selection.
NOTE:
_
• The tachometer mode is executed and it is
displayed on the tripmeter 1 LCD.
•“C1” appears on the odometer/fuel reserve
tripmeter/tripmeter 2 LCD.
5. Press the “SELECT” and “RESET” buttons
to change the CO adjustment volume.
NOTE:
_
The CO adjustment volume appears on the
odometer/fuel reserve tripmeter/tripmeter 2
LCD.
• To decrease the CO adjustment volume,
press the “RESET” button.
• To increase the CO adjustment volume,
press the “SELECT” button.
6. Release the switch to execute the selection.
7. Turn the main switch to “OFF” to cancel the
mode.