8 - 61
– +
ELEC
IMMOBILIZER SYSTEM
2. The multifunction display is not indicated.
YES
NO
1. Voltage
• Connect the pocket tester (DC 20 V) to the
meter assembly couplers as shown.
Positive tester probe
→
red/green
1
and red/white
3
Negative tester probe
→
black/white
2
• Turn the main switch to “ON”.
• Measure the voltage (DC 12 V) meter
assembly couplers (wire harness end).
• Is the voltage within specification?
Replace the meter
assembly.
The wiring circuit
from the main switch
to the meter assem-
bly couplers is faulty
and must be
repaired.
Dg
G/L
R/W
Ch
R/G
Y
B/W
Lg
G/W
Y/L
Ch R/G
Y
G
G/L
R/W
G/W
Y/L
B/W
Lg
1
2
3