Symmetricom 59551A GPS Receiver User Manual


 
Chapter 5 Command Reference
Programmable Pulse Output (59551A Only)
Operating and Programming Guide 5-87
59551A
This command identifies the date when the individual pulse (or first pulse of
the pulse sequence) is generated at the Programmable Pulse output.
Expanded Syntax
:PULSe:STARt:DATE <four-digit year>,<month>,<day>
Parameter
The <four-digit year> range is 1994 to 3000.
The <month> range is 1 to 12.
The <day> range is 1 to 31.
Context Dependencies
If you select a date and time which occurs prior to the current time or prior to
the completion of powerup and first GPS lock, the Receiver will not successfully
find a start—and therefore will produce no pulses.
If the Receiver has been set up to use a time zone offset to produce local date
and time, the parameters provided should also be expressed as local date and
time.
59551A
This query returns the date when the individual pulse (or first pulse of the
pulse sequence) is generated at the Programmable Pulse output. This query
returns year, month, and day.
Response
Three fields are separated by commas: <four-digit year>,<month>,<day>.
The <four-digit year> range is 1994 to 3000.
The <month> range is 1 to 12.
The <day> range is 1 to 31.
:PULSe:STARt:DATE . . .
:SYSTem:PRESet
Identifies the date when the individual pulse (or first pulse of the
pulse sequence) is generated at the Programmable Pulse output.
1994, 1, 1
NON-VOLATILE
:PULSe:STARt:DATE?
RESPONSE FORMAT
Returns the date when the individual pulse (or first pulse of the
pulse sequence) is generated at the Programmable Pulse output.
± dd, ± dd, ± dd