Chapter 5 Command Reference
Operating Status
5-66 Operating and Programming Guide
Monitoring Status/Alarm Conditions ___________
(continued)
!
Reading and Qualifying Command Error Status ____________
Figure 5-4. Command Error Event and Enable Registers
The setting of the Command Error Enable Register (Figure 5-4) selects which
events from the Command Error Event Register are enabled to report to the
Command Error Summary bit of the Alarm Condition Register.
Expanded Syntax
*ESE <bit mask>
Parameter
The <bit mask> has a range of 0 to 255.
The <bit mask> value represents the sum of the binary-weighted values of the
register. Attempts to set unused bits in the register are ignored—the value of
unused bits is zero.
*ESE . . .
:SYSTem:PRESet
Sets the Command Error Enable Register.
0
NON-VOLATILE
Command Error
Enable
Register
3
Query Error
"OR"
not used
not used
not used
7
5
Hardware/Firmware Error
Syntactic Error
Power Cycled
Command Error
Summary Bit of
Alarm Condition
Register
&
&
&
Command Error
Event
Register
3
not used
not used
not used
Query Error
Semantic Error
7
5
Hardware/Firmware Error
Syntactic Error
Power Cycled
*
ESR?
*
ESE <bit mask>
*
ESE?
"AND"
&
&
4
2
Semantic Error
2
4