Furuno FR-2125V Radar Detector User Manual


 
1-22
1.20 Measuring Range and Bearing Between Two
Targets
1. Press the [EBL OFFSET] key, and place the origin of the No. 1 EBL, for example, on a
target of interest (target 1 in the illustrated example), by operating the trackball.
2. Turn the EBL control until the EBL passes through another target of interest (target 2).
3. Turn the VRM control until the range marker aligns with target 2. The active VRM
readout at the lower-right corner of the screen indicates the distance between the two
targets.
You can repeat the same procedure on third and fourth targets by using the No. 2 EBL
and No. 2 VRM.
Bearing is shown relative to own ship with suffix “R” or as a true bearing with the suffix
“T” depending on EBL relative/true settings on the RADAR 1 menu.
5. To return the EBL origin to the own ship position, press the [EBL OFFSET] key again.
000
010
020
030
040
050
060
070
080
090
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
EBL origin
VRM
> 0.500SM<
0.980SM
EBL
> 140.0°T<
335.2°T
R1
R2
No.1 VRM
No.2 VRM
Target 1
Target 2
Range marker
No.1 EBL
Range/bearing between targets 1 and 2
Figure 1-23 Measuring range and bearing between two targets