Multiquip DCA150USJ2 Automobile Parts User Manual


 

ENGINE OPERATING PANEL
Figure 6. Engine Operating Panel
AUTO
MANUAL
OFF/RESET
LOWOILPRESSURE
HIGHCOOLANTTEMPERATURE
OVERCRANK
OVERSPEED
ENGINERUNNING
MOOOOO-20001Q
1
14
7
8
9
10
11
3
5
4
13
12
2
6
OFF
W
U
V
OFF
W-U
V-W
U-V
DECREASE
INCREASE
The definitions below describe the controls and functions
of the Engine Operating Panel (Figure 6).
1.    When activated will turn on
control panel light.
2. Normally used in dark areas or at night
time. When activated, panel lights will illuminate. When
the generator is not in use be sure to turn the panel
light switch to the OFF position.
3.   As the engine cranks, this lamp
will illuminate to indicate automatic preheating of the
engine. When the lamp turns off, the engine has been
preheated and will start automatically.
4.    This lamp will illuminate when a
critical engine fault has occured.
5. This lamp will illuminate
when the emergency stop button has been pressed
or a critical engine fault has occured.
6.    This lamp will
illuminate when a leak in the fuel tank containment
enclosure is detected.
7.
  During normal operation this
gauge be should read between 35 to 65 psi. (241~448
kPa). When starting the generator the oil pressure may
read a little higher, but after the engine warms up the
oilpressure should return to the correct pressure range.
8. During normal operation
this gauge be should read between 180° and 221°F. (82°
C and 110° C
9.   Indicates the current
being supplied by the engine’s alternator which
provides current for generator’s control circuits and
battery charging system.
10.
ndicates amount of diesel fuel available.