Furuno Marine Radar Radar Detector User Manual


 
SP - 4 E3502S01C
C-MAP chart card also available for C-MAP NT Model
5.14. Alarms Arrival and Anchor watch, Cross track error and proximity
alarms, Ship’s speed in and out alarms, Water temperature,
Trip alarm, Fish alarm, Bottom alarm (ETR required)
6. POWER SUPPLY
6.1. Rated Voltage/Current
M1833: 12-24 VDC: 5.0-2.5 A
M1933: 12-24 VDC: 6.5-3.2 A
M1943: 12-24 VDC: 7.2-3.7 A
6.2. Rectifier (option)
PR-62 (M1833): 100/110/220/230 VAC, 1 phase, 50/60 Hz
RU-3423 (M1933/1943): 100/110/220/230 VAC, 1 phase, 50/60 Hz
7. ENVIRONMENTAL CONDITION
7.1. Ambient Temperature Scanner Unit: -25°C to +70°C
Display Unit: -15°C to +55°C
Remote Controller: +5°C to +45°C
7.2. Relative Humidity 93 % or less at +40°C
7.3. Waterproofing Scanner Unit: IPX6
Display Unit: IPX5 (External monitor connected: IPX0)
Remote Controller: IPX0
7.4. Bearing Vibration IEC 60945-3rd
8. COATING COLOR
8.1. Display Unit N3.0
8.2. Scanner Unit
M1833: N9.5 (upper), 2.5PB3.5/10 (lower)
M1933/1943 N9.5
9. COMPASS SAFE DISTANCE
9.1. Display Unit Standard: 0.85 m Steering: 0.45 m
9.2. Scanner Unit
M1833 Standard: 0.90 m Steering: 0.70 m
M1933/1943 Standard: 1.00 m Steering: 0.75 m